Detail Belden 1063A - 18 AWG 2 Pair - Kabel Kontrol - UL Instrumentation
PT. VISINDO GLOBAL TEKNOLOGI adalah MASTER DEALER untuk Produk Belden seperti Kabel 1063A - 18 AWG 2 Pair - Kabel Kontrol dengan spesifikasi sbb :
Product: 1063A
Inst, 2 Pr #18 Str BC, PVC-NYL Ins E1, OS, Blk PVC Jkt, 600V TC-ER 150V
NPLF 90C Dry/Wet
Product Description
UL Instrumentation, 2 Pair 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER
150V NPLF 90C Dry/Wet SUN RES DIR BUR
Technical Specifications
Product Overview
Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control
system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners
Construction Details
Conductor
Element No. of Elements Size Stranding Material
Pair(s) 2 18 AWG 7x26 BC - Bare Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PVC/Nylon - Polyvinyl Chloride + Nylon 0.022 in (0.56 mm) 0.088 in (2.2 mm) ICEA Chart E1
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 18 AWG (7x26) TC
Outer Jacket
Material Nom. Thickness Nom. Diameter Ripcord
PVC - Polyvinyl Chloride 0.047 in (1.2 mm) 0.405 in (10.3 mm) Yes
Overall Cable Diameter
(Nominal): 0.405 in (10.3 mm)
Electrical Characteristics
Electricals
Element Nom. Conductor DCR Max. Current
Pair(s) 6.93 Ohm/1000ft 11 Amps per conductor @ 30°C
Voltage
UL Voltage Rating
600 V (TC-ER), 150 V (NPLF)
Mechanical Characteristics
Temperature
UL Temperature Operating
90°C Dry, 90°C Wet -30°C to 90°C Dry/Wet
Bend Radius
Stationary Min. Installation Min.
4.9 in (120 mm) 4.9 in (120 mm)
Max. Pull Tension: 112 lbs (50.8 kg)
Bulk Cable Weight: 67 lbs/1000ft
Standards and Compliance
Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to
Fire: UL 1685 FT4 Loading, FT4, IEEE 1202 FT4
NEC / UL Compliance: Article 336, Article 760, NPLF, TC-ER
European Directive
Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
History
Update and Revision: Revision Number: 0.603 Revision Date: 01-04-2024
Part Numbers
Variants
Item # Color Putup Type Length UPC Footnote
1063A 01010000 Black Reel 10,000 ft 612825105657 C Z
© 2024 Belden, Inc.
https://catalog.belden.com/techdata/EN/1063A_techdata.pdf