Detail Belden Industrial Kabel UTP Cat 6 - 50106UAL - Armored 24 AWG LSZH
PT. VISINDO GLOBAL TEKNOLOGI adalah MASTER DEALER untuk Produk Belden seperti Industrial Kabel UTP Cat 6 - 50106UAL - 24 AWG LSZH dengan spesifikasi sbb :
Technical Data Sheet
Industrial Armored Category 6 UTP LSZH Cable
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden P/N 50106UAL
Armoured Industrial Category 6 UTP LSZH Cable
Applications
Industrial Ethernet cables are used for interconnecting Industrial Ethernet Switches, IP controllers, media convertors,
distributed control system, programmable logic controller and transmitting industrial protocol data signals. These cables
are suitable for transmitting 1000BASE-TX Gigabit Ethernet, 100BASE-T Ethernet, 100BaseVG ANYLAN, 155ATM, 622ATM,
RS-422, 250MHz Category 6, EtherCAT. These are highly durable & ruggedized cables for both indoor and outdoor use
meeting IEC 60332-3-24 and IEC 60754-1 & 2
General Reference Standards
IEC/ISO 11801, IEC 61156-5 & TIA-568 -C.2
IEC 60332-3-24, 60754-1, 60754-2, 61034-2
EU RoHS
Physical Characteristics Electrical Characteristics
Conductor Size 24 AWG Max. Conductor DCR @ 20°C 9.38 Ω/100m
Conductor Material Solid Bare Copper DCR Unbalance @ 20°C Max. 5%
Insulation Material PO - Polyolefin
Number of Pairs 4 Pairs Nom. Mutual Capacitance @
1KHz 5.6 nF/100m
Overall cabling filler Central Spline
Armor Aluminium Tape Armor (ATA) Max. Capacitance Unbalance 330 pF/100m
Outer jacket Ripcord Yes
Outer Jacket LSZH – Low Smoke Zero Halogen Characteristic Impedance 100 ± 15 Ω
Nom. Diameter 9.0 mm
Suitability Indoor and Outdoor Max. Delay @ 100MHz 538 ns/100m
UV Resistance Yes
Oil Resistance Yes Max. Delay Skew 45 ns/100m
Flame Retardant IEC 60332-3-24
Other Specifications
ISO/IEC 11801 Category 6
IEC 61156-5 Category 6
TIA/EIA 568-C.2 Category 6
Max. Intended Operating Voltage 300V RMS
Mechanical Characteristics Other Properties
Operating
Temperature Range -20°C To +75°C Halogen Content per IEC 60754-1 ≤ 5 mg/g
Bulk Cable Weight 80 kg/km Acid Gas Emission pH per IEC
60754-2 ≥ 4.3
Max. Recommended
Pulling Tension 110 N Acid Gas Emission Conductivity
per IEC 60754-2 < 10 μs/mm
Min. Bending Radius
(Install) 72 mm Smoke Density as per IEC 61034-2 ≥ 60% Light
Transmittance
Technical Data Sheet
Industrial Armored Category 6 UTP LSZH Cable
2
© 2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Electrical Characteristic - Premises:
Frequency
(MHz)
Max. Attenuation
(dB/100m)
Min. NEXT
(dB)
Min. PSNEXT
(dB)
Min. Return
Loss (dB)
Min. ACRF
(dB)
Min. PSACRF
(dB)
1 2.0 74.3 72.3 20.0 67.8 64.8
4 3.8 65.3 63.3 23.0 55.8 52.8
8 5.3 60.8 58.8 24.5 49.7 46.7
10 6.0 59.3 57.3 25.0 47.8 44.8
16 7.6 56.2 54.2 25.0 43.7 40.7
20 8.5 54.8 52.8 25.0 41.8 38.8
25 9.5 53.3 51.3 24.3 39.8 36.8
31.25 10.7 51.9 49.9 23.6 37.9 34.9
62.5 15.4 47.4 45.4 21.5 31.9 28.9
100 19.8 44.3 42.3 20.1 27.8 24.8
155 25.2 41.4 39.4 18.8 24.0 21.0
200 29.0 39.8 37.8 18.0 21.8 18.8
250 32.8 38.3 36.3 17.3 19.8 16.8
Put Ups & Colours:
Revision Number:1 Revision Date: 15/11/2017
Stock Code Cable Description Put Up (MT) Jacket Colour Ship Weight
(kg/reel)
50106UAL 006305M 4P X 24 AWG PO LSZH UTP CAT6 ARMOR 305 BLU 24.4
50106UAL 008305M 4P X 24 AWG PO LSZH UTP CAT6 ARMOR 305 GRY 24.4
50106UAL 010305M 4P X 24 AWG PO LSZH UTP CAT6 ARMOR 305 BLK 24.4.
https://www.denko.co.id/download/Category_Cabling_System/Cables/CAT6/50106UAL(2017)ME.pdf
Untuk mendapatkan harga terbaik , di mohon untuk menghubungi sales kami.
HARGA NEGO.............................................................
VINSEN / LASMI
PT. VISINDO GLOBAL TEKNOLOGI
Mangga Dua Square Lt. 2 Blok B No. 010 - 012
Jl. Gunung Sahari Raya No. 1 Jakarta Utara
Tampilkan Lebih Banyak